中山市TBT预警防控平台
——技术性贸易措施资源
|
双管空调
|
单管空调
|
||||||
|
2013.1.1
|
2014.1.1
|
2013.1.1
|
2014.1.1
|
||||
|
EER额定
|
COP额定
|
EER额定
|
COP额定
|
EER额定
|
COP额定
|
EER额定
|
COP额定
|
制冷剂GWP>150
|
2.40
|
2.36
|
2.60
|
2.60
|
2.40
|
1.80
|
2.60
|
2.04
|
制冷剂GWP£150
|
2.16
|
2.12
|
2.34
|
2.34
|
2.16
|
1.62
|
2.34
|
1.843
|
|
|
2013.1.1
|
2014.1.1
|
||
|
|
SEER
|
SCOP
|
SEER
|
SCOP
|
制冷剂GWP>150
|
< 6 kW
|
3.60
|
3.40
|
4.60
|
3.80
|
6~12 kW
|
|
4.30
|
3.80
|
||
制冷剂GWP£150
|
< 6 kW
|
3.24
|
3.06
|
4.30
|
3.80
|
6~12 kW
|
|
|
3.87
|
3.42
|
|
第一阶段(2013.1.1)
|
第二阶段(2014.1.1)
|
|
关机模式
|
£ 1 W
|
£ 0.5 W
|
|
待机模式
|
重新激活
|
£ 1 W
|
£ 0.5 W
|
信息与状态显示
|
£ 2 W
|
£ 1 W
|
|
提供待关机模式
|
有
|
有
|
|
电源管理
|
无
|
有(以可能最短的时间自动切换到待关机模式)
|
额定制冷/热量£ 6 kW
|
6 < 额定制冷/热量£ 12 kW
|
||
室内声功率最大值
|
室外声功率最大值
|
室内声功率最大值
|
室外声功率最大值
|
60
|
65
|
65
|
70
|
测试参数
|
标准编号
|
标准名称
|
能效比(EER)、
性能系数(COP)
|
EN 14511:2007
|
Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling
|
能效比(EER)
|
EN 15218:2006
|
Air conditioners and liquid chilling packages with evaporatively cooled condensor and with electrically driven compressors for space cooling
|
季节能效比(SEER)、季节性能系数(SCOP)
|
PrEN 14825:2011
chapter 8 and 9
|
Air conditioners, liquid chilling packages and heat pumps, with electrical compressors, for space heating and cooling – Testing and rating at part load conditions and calculation of seasonal performance
|
待机功耗
|
EN 62301:2005
|
Household Electrical Appliances: Measurement of standby power
|
空调声功率级
|
EN 12102:2008
|
Air conditioners, liquid chilling packages, heat pumps and dehumidifiers with electrically driven compressors for space heating and cooling - Measurement of airborne noise - Determination of the sound power
|
风扇能效
|
IEC 60879:1986 (corr. 1992)
|
Performance and construction of electric circulating fans and regulators
|
风扇声功率级
|
EN 60704-2-7:1997
|
Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 2: Particular requirements for fans
|